Endoscopic Retrieval Pouches

Endo Pouch with Suture Tie

One of three models of Endo Pouches available to retrieve specimens during endoscopic surgery.

Product Features

Hi-Strength Polyurethane Pouch Material Assures No Leakage
Tapered Bag Design Allows for Easier Removal
10mm Introducer Provides Ease of Insertion
Cost-Effective and Multi-Functional

1. Remove the Endo Pouch with Suture Tie from the package.

2. Insert the device through the desired 10mm, 11mm, or 12mm trocar sheath.

3. To remove the pouch from the dispensing tube, grasp the exposed pouch at the distal end of the tube and carefully withdraw the pouch out from the tube. Keep the suture out of the cavity.

4. Place desired specimen into the pouch (ensure the entire specimen fits within the confines of the pouch) and grasp the pouch at the suture knot. Pull the end of the suture loop until the pouch is closed.

5. Remove the endo pouch at the end of the laparoscopic procedure. To remove the pouch, use graspers to pull the top of the pouch into the distal end of the trocar sheath. While securing the pouch with grasper, withdraw the trocar sheath, pouch, and graspers through the incision site until leading edge of the pouch can be visualized. Continue removing the pouch from the incision site by hand under eye vision.

6. Upon completion of the endoscopic procedure, dispose the device in accordance with local regulation.

To order Endo Pouches and related products, use the following table for reference when talking with your Tech-Medical representative.

Item Order Code Details
ENDO POUCH WITH SUTURE TIE 3” x 6” TM3000T 20 Each/Box
ENDO POUCH WITH SUTURE TIE 5” x 7” TM3001T 20 Each/Box

1. Remove the Endo Pouch with Suture Tie from the package.

2. Insert the device through the desired 10mm, 11mm, or 12mm trocar sheath.

3. To remove the pouch from the dispensing tube, grasp the exposed pouch at the distal end of the tube and carefully withdraw the pouch out from the tube. Keep the suture out of the cavity.

4. Place desired specimen into the pouch (ensure the entire specimen fits within the confines of the pouch) and grasp the pouch at the suture knot. Pull the end of the suture loop until the pouch is closed.

5. Remove the endo pouch at the end of the laparoscopic procedure. To remove the pouch, use graspers to pull the top of the pouch into the distal end of the trocar sheath. While securing the pouch with grasper, withdraw the trocar sheath, pouch, and graspers through the incision site until leading edge of the pouch can be visualized. Continue removing the pouch from the incision site by hand under eye vision.

6. Upon completion of the endoscopic procedure, dispose the device in accordance with local regulation.

To order Endo Pouches and related products, use the following table for reference when talking with your Tech-Medical representative.

Item Order Code Details
ENDO POUCH WITH SUTURE TIE 3” x 6” TM3000T 20 Each/Box
ENDO POUCH WITH SUTURE TIE 5” x 7” TM3001T 20 Each/Box

Explore Related Products

View Product

Endoscopic Retrieval Pouches

Endo Pouch with Memory Wire

View Product

Endoscopic Retrieval Pouches

Detachable Endo Retrieval Pouch

View Product

Endoscopic Retrieval Pouches

Endo Pouch with Introducer

Get a quote, request a trial, or start a conversation with one of our expert representatives.

Request Info